AJ-FFP organizes training for fire department trainers. The training can be done online, and that’s why the fire department's own organization can easily train its own firefighters.
If you would like to learn more about the online training, please contact us!
The vaporization of water binds energy and the fire goes out when the temperature drops low enough. Reducing the diameter of the water droplet increases the contact area. So that we can get the largest possible contact surface for the water drop. We have to break a drop of water in the nozzle. Bernoulli's principle helps here.
We increase the speed of the water by using nozzle acceleration funnels. After this, a fast stream of water hits the reflective surface and we get a small droplet of water mist.
With a water droplet diameter of 0.3-0.4 mm, a contact surface area is 20 m2 is obtained from 1 liter of water. By reducing the water drop to a diameter of 0.15 mm, the result is more than 30 m2
The viscosity of water changes as the temperature changes.
At 20 °C, the viscosity of water is 1.0016 mPa·S
At 10 °C, the viscosity of water is 1.3059 mPa·S
This means that the water pressure must be increased when the temperature drops, so that we get a sufficiently high shower pressure.
A standard hoze-nozzle sucks in air along with the water flow. This transfers oxygen to the fire target. A bigger problem is the unfavorable air flow along with the water flow. This airflow isolates the water droplets from the hot combustion gases, preventing maximum vaporization. This problem does not exist with AJ-FFP because the water jet is produced inside the fire target.
In order to maximize the vaporization of the small droplet water mist, we need to move the AJ-FFP back and forth in the burning room or cavity. We take the nozzle in the space to every place where there are hot fire gases. Look at the color of the combustion gases. When the color changes to white vapor, the flames in the room have gone out andyou can switch to extinguishing the fire from the wall on the side of the opening
After the flames in the room are extinguished, we hold the nozzle for a few more seconds inside the window opening so that the wall facing the window is extinguished. All rooms must be turned off one after the other. Make sure that already extinguished spaces do not light up again.
The valve has 2 positions.
Copyright © 2024 AJ-FFP FireFightingPole GlobalFireFightingPole Ari-Jukka Kalliomäki- All Rights Reserved.